Ontwerp en bouw van ontslakker, schacht en transportsysteem van 3 verbrandingslijnen

EF16Contract notice – general directive, standard regimef37ad02b-c182-4179-a7d6-a35c272dc748TBTwence Holding B.V.
86 days left
Estimated value€5,500,000
Deadline86 days left30 Dec 2026, 23:00
Competition00 participants
Lots11 lot

Keep momentum on this opportunity

Save it on this device now. Create an account when you are ready to track deadlines, notes, and teamwork.

  • Save and reuse search filters
  • Track opportunities as pursuits
  • Get notified when new notices match
Quick actions

Keep this notice in a shortlist so you can return to it without starting a bid.

Keep notes, monitor deadlines and collaborate with your team. This does not submit a bid or contact the buyer.

Receive alerts

Key information

Contract type
—
Deadline
30 Dec 2026, 23:00
CPV codes
45252300 - Refuse-incineration plant construction work
Status
Active
Notice type
EF16Contract notice – general directive, standard regime
Source
Estimated value
€5,500,000
Publication date
21 Feb 2024, 14:44

Overview

Initiële opdracht: 1. Ontwerp (engineering) en constructie (fabricage, levering en de- en montage) voor de vervanging van de schacht en ontslakker van verbrandingslijn 1 en 2. De battery limit van de initiële opdracht: vanaf de afworp van het rooster, de aansluiting van de schacht op de doorvalkanaal van het rooster, tot de uitwerpopening in de slakkenbunker, aanpassingen aan bordessen en doorvoeren, E&I, besturing en hydrauliek voorzieningen voor het correct laten functioneren van de nieuwe installatie delen; 2. Bijbehorende documentatie conform Twence eisen lijn 1 en 2; Onderhoud van 2 jaar tijdens de garantieperiode en een periode van 2 jaar na garantietermijn voor lijn 1 en 2. 4. Optimaliseren van de semi droog bedrijfsvoering: zoals elimineren stofemissie, slijtage vermindering en temperatuurbeheersing; 5. Ontwerp (engineering) en constructie (fabricage, levering en de- en montage) transportsysteem van de bodemassen na uitworp ontslakkers voor verbrandingslijnen 1 en 2; 6. Ontwerp (engineering en adviseren) en constructie (fabricage, levering en de- en montage) schuifafsluiter slakkenschacht in lijn 1 en 2. Optionele opdracht 1. Ontwerp (engineering) en constructie (fabricage, levering en de- en montage) voor de vervanging van de schacht en ontslakker van verbrandingslijn 3. De battery limit van de optionele opdracht: vanaf de afworp van het rooster, de aansluiting van de schacht op het doorvalkanaal van het rooster, tot de uitwerpopening in de slakkenbunker, aanpassingen aan bordessen en doorvoeren, E&I, besturing en hydrauliek voorzieningen voor het correct laten functioneren van de nieuwe installatie delen; 2. Bijbehorende documentatie conform Twence eisen lijn 3. 3. Onderhoud van 2 jaar tijdens de garantieperiode en een periode van 2 jaar na de garantieperiode voor lijn 3; 4. Transportsysteem van de bodemassen na uitworp ontslakkers voor verbrandingslijnen 3; Ontwerp (engineering en adviseren) en constructie (fabricage, levering en de- en montage) 5. Schuifafsluiter slakkenschacht in lijn 3.

Initial assignment: 1. Design ( engineering ) and construction ( manufacturing, delivery and assembly) for the replacement of the shaft and deslagger of combustion lines 1 and 2. The battery limit of the initial assignment: from the throw-off of the grille, the connection of the shaft to the bottem ash handlingystem (transfer channel) of the grille, to the ejection opening in the deslakker bunker, adjustments to platforms and penetrations, E&I, control and hydraulic facilities for the correct functioning of the new installation parts; 2. Associated documentation in accordance with Twence requirements lines 1 and 2; 3. Maintenance of 2 years during the warranty period and a period of 2 years after warranty period for lines 1 and 2. 4. Optimizing semi-dry operations: such as eliminating dust emissions, wear reduction and temperature control; 5. Design ( engineering ) and construction ( manufacturing, delivery and installation ) transport system of the bottom ashes after ejection of deslaggers for combustion lines 1 and 2; 6. Design ( engineering and advising ) and construction ( manufacturing, delivery and installation ) of the slag chute gate valve in the shafts of lines 1 and 2. Optional assignment 1. Design ( engineering ) and construction ( manufacturing, delivery and installation ) for the replacement of the shaft and deslagger of combustion line 3. The battery limit of the optional command: from the throw-off of the grille, the connection of the shaft to the bottem ash handlingystem (transfer channel) of the grille, to the ejection opening in the deslakker bunker, adjustments to platforms and penetrations, E&I, control and hydraulic facilities for the correct functioning of the new installation parts; 2. Associated documentation in accordance with Twence requirements line 3. 3. 2-year maintenance during the warranty period and 2 years after the warranty period for line 3; 4. Transport system of the bottom ashes after ejection of deslaggers for combustion lines 3; 5. Design ( engineering and advice ) and construction ( manufacturing, delivery and installation ) slag chute gate valve in the shaft of line 3.

Contracting authorities1

TB

UNKNOWN 08090697

nlHengelo, Netherlands
[email protected]

Lots1

Documentation0

Documents have not been synced yet. Last checked 5 Oct 2026, 05:27.

Award criteria0

No procedure-level award criteria recorded.

Participants0

No participants recorded for this notice.