Electrical Installation Condition Reporting (EICR) Services

UK2Preliminary market engagement notice090383-2026MTMid and South Essex NHS Foundation Trust
Estimated value£300,000
Deadline—
Competition00 participants
Lots11 lot

Keep momentum on this opportunity

Save it on this device now. Create an account when you are ready to track deadlines, notes, and teamwork.

  • Save and reuse search filters
  • Track opportunities as pursuits
  • Get notified when new notices match
Quick actions

Keep this notice in a shortlist so you can return to it without starting a bid.

Keep notes, monitor deadlines and collaborate with your team. This does not submit a bid or contact the buyer.

Receive alerts

Key information

Identifier
Contract type
—
Deadline
—
CPV codes
71314100 - Electrical services45310000 - Electrical installation work50711000 - Repair and maintenance services of electrical building installations71630000 - Technical inspection and testing services
Status
Planning
Notice type
UK2Preliminary market engagement notice
Estimated value
£300,000
Publication date
24 Sept 2026, 07:54

Overview

Mid and South Essex University Hospitals NHS Foundation Trust (the Trust) is seeking information from suitably qualified and experienced suppliers capable of undertaking Electrical Installation Condition Reports (EICRs) across occupied and operational healthcare facilities using non-disruptive or minimally disruptive testing methodologies. The Trust operates critical healthcare environments that function continuously and therefore requires electrical compliance inspections and testing to be undertaken in a manner that maintains patient safety, supports uninterrupted clinical operations, and minimises disruption to essential services wherever reasonably practicable Scope of Requirement Suppliers are invited to provide information relating to their capability, experience, and methodology for undertaking EICRs within live healthcare environments, including acute hospital sites operating on a 24-hour basis. The Trust seeks a solution that: • Delivers statutory and regulatory compliance. • Minimises the need for planned electrical outages. • Reduces operational disruption to clinical services. • Maintains patient safety and business continuity. • Provides a robust and auditable inspection and testing process. 3. Applicable Standards and Compliance Requirements Suppliers shall demonstrate compliance with all relevant legislation, standards and guidance, including but not limited to: • BS 7671: Requirements for Electrical Installations (current edition). • IET Guidance Note 3: Inspection and Testing. • Electricity at Work Regulations 1989. • HTM 06-01: Electrical Services Supply and Distribution. • HTM 06-02: Electrical Safety Guidance for Low Voltage Systems. • NHS Premises Assurance Model (PAM) requirements where applicable. • NICEIC, ECA, NAPIT or equivalent accredited inspection and testing procedures. Suppliers should demonstrate how their proposed testing methodology satisfies the above requirements whilst supporting the Trust's objective of maintaining service continuity. Testing Without Service Disruption The Trust's preference is for inspection and testing methodologies that minimise or eliminate disruption to clinical and operational services wherever possible. Suppliers shall clearly describe how they will conduct EICRs within operational healthcare facilities whilst avoiding unnecessary interruption to electrical supplies serving critical services. Important clarification The Trust recognizes that certain inspection and testing activities required under BS 7671 may necessitate temporary electrical isolation. The requirement is therefore to avoid unnecessary disruption, apply all reasonably practicable non-disruptive methods first, and tightly control any unavoidable isolation. Where isolation is required, suppliers shall: • Demonstrate that all reasonably practicable non-disruptive testing techniques have been considered. • Clearly identify those tests that require electrical isolation. • Minimise the extent and duration of each isolation. • Provide detailed risk assessments and method statements. • Coordinate all planned outages with the Trust's Estates and Facilities teams. • Maintain continuity of patient care through suitable contingency arrangements. • Provide advance notification of outage requirements. • Clearly define mitigation measures and recovery procedures. • Demonstrate experience in managing electrical testing within live healthcare environments. Suppliers are encouraged to describe any specialist technologies, equipment, software, or recognised industry methodologies that enable condition assessment, fault identification, and compliance verification whilst systems remain energized and operational.

Procurement Act 2023

Please send all enquires to [email protected] the closing date for enquires are 07/10/2026

Contracting authorities1

MT

PPON PBVJ-9475-ZCMD

gbBasildon, United Kingdom
[email protected]

Lots1

Documentation0

Documents have not been synced yet. Last checked 21 Oct 2026, 21:17.

Award criteria0

No procedure-level award criteria recorded.

Participants0

No participants recorded for this notice.